A standardized solution at hand for fridge.

TE.M - Advantages

• intended for refrigeration equipment up to 32A;
• Equipped with Dixell controller which allows you to control temperature, the degivrarii and fans;

  • Ensure the protection of motors and automatic electrical circuits;
  • Offers a choice of drive mode of the compressor pump-down or directly;
  • Standardized solution that allows in a short space of time automation refrigeration equipment.

TE.M - Description

Panels series TE.M standard are equipped with :

  • electronic  regulator temperature, with 3 relays, type Dixell (ITALY) which command: 

-starting and stopping the engine compressor electrical,
- the opening and closing of the tap mounted electromagnetic pipe liquid agent at the evaporator inlet,
- turn on or off fan electric motors vaporizatoarelor,
- initiation and end degivrarii.

The alarm for condenser by sensors 3° or 4° are able to have an additional alarms for temperature condenser. This parameter can be used to switch off the installation. (NB: only possible for Standard controller)

It may also provide communication with the monitoring system XWeb 300/500.

  • switch sectioner general 20 / 32 / 40 A
  • circuit breaker actuator from the outside magneto-thermal protection for compressor motor (except compressors variants for single phase in which the protection fuse is made by automatic)
  • compressor motor drive switch;
  • fan motor drive switch condenser;
  • fan motor drive switch evaporator;
  • drive switch resistance defrost;
  • red light hazard flasher unit.
  • automatic safety for the protection of the control circuit;
  • automatic fuse protection for fan motors;
  • connectors for selection of drive mode of the compressor: directly or pump-down;
  • connectors for pressure switch connection combined - type KP 15 - or equivalent;

 

Electrical panel box has degree of protection IP 55 , is made out of a sheet continue the steel sheet double faltuita at the front of the device and with the rear part welded to the framework of resistance and is protected inside and out with the resin poliesterica and with gray spray paint RAL-7032 textured.


Unit size for models TEM is 500 * 400 * 150mm or 600 * 500 * 150mm.

TE.M- Options OM1 - OM16

Through the options OM1-OM16 offers additional items of automation, protection and customization.

Option "OM1" - ADDITIONAL PROTECTION COMPRESSOR

  • connectors for differential pressure switch - oil type MP54 or equivalent ( (OLC-K1)
  • connectors for termic protection compressor - INT69 or echivalent(SE-B1).


Option "OM2" - SERIAL INTERFACE RS485 Hazard FOR THE SYSTEM MONITORING

  • serial interface type RS 485 compatible with the monitoring system Xweb300 / 500. The monitoring program allows you to read and record following information: size numbers controlled, the statuses of the hazard warning and operation, connectors for RS 485.

Option "OM3" - SYSTEM PUMP-DOWN

  • connectors for connection of the pressure switch low pressure (low pressure).

Option "OM4" - SYSTEM PUMP-OUT

  • connectors for connection of pressure switch low pressure (Low Pressure),
  • additional control relay, UPON control, for the purpose of carrying out system pump-out.

Option "OM5" - THE SWITCHES FOR THE CONTROL CIRCUIT - N/A option


Option "OM6" - CHECK PRESSURE RELIEF IN TWO STEPS FROM THE CONDENSATION

  • pressure switch connectors for connection of high pressure (High Pressure);
  • switch and additional stirrer for the second fan of the circuit from the condensation.

Option "OM7" - EQUIPMENT MULTIFUNCTION CONTROLLER SPLIT - XW60K and keyboard V620 for situations where it is desirable to force the panel placement next to profile, and the plant beside the door control cold store.

 

  • electronic thermostat type "WING" split- XW60K - allows for both starting and stopping installation directly on the keyboard. Lighting in the room cold may also be switched on or off in automatic mode or directly on the keyboard. The thermostat can be programd with a "digital key".
Option "OM8" - EXTRA POWER SUPPLY

 

  • protection circuit additionally be carried out with an automatic fuse (10A) (for power holster resistance door, valve circuit depression or lighting).

Option "OM9" - PROTECTION panel CABLES 

  • GLANDS can be equipped with glands PVC jacket for crossing cables at the bottom.

Option "OM10" - CUSTOM

  • schematic diagram customization PANEL panel with the data for the identification of the customer, any header.

Option "OM11" - PANEL FITTED WITH THERMOSTATIC CONTROL OF TWO coolers - XR64CX

  • protective circuit and the command for Antiicing resistance on second cooler, including temperature sensor.

Option "OM12" - MONITORING asymmetry, THE LACK OF A PHASE

  • monitoring relay supply voltage with asymmetry phases, as well as a lack a phase
  • setting the stroke to trigger or relay working.

Option "OM13" - COMPREHENSIVE MONITORING PHASE

  • voltage monitoring relay supply asymmetry to trigger phases,
  • the lack of a phase, minimum voltage, maximum voltage, set the stroke to trigger or relay working.

Option "OM14" - STARTING COMPRESSOR PARTI-WIDING

  • switch, relay of time and connectors to the second winding of the motor (type connection double star YY or parti-widing).

Option "OM15" - HAZARD WARNING CONDENSING PRESSURE (only valid in standard controller - XR60CX)

  • additional temperature sensor for visual signalling of damage from the condensation.

Option "OM16" - METAL BOX 600x500x150 MM

  • will use a metal box of large size (600x500x150mm) than in standard (500x400x150mm).