REGULATOR  CHARACTERISTICS SENSORS             FUNCTIONS
 XR20CX Digital Controller on/off
Output: 1 relay
NTC:NG6 –40C-+100C
PTC: S6SH –50C-+150C
  • digital settings
  • functional in applications for heating / cooling
  • configurable digital inputs (door alarm)
  • icing by stopping the compressor
  • reducing energy consumption function Save Energy
  • quick programming with HOTKEY function
  • TTL output that allows connection to monitoring systems Xweb
 XR60CX Digital Controller on/off
Output: 3 relay
NTC:NG6 –40C-+100C
PTC: S6SH –50C-+150C
  • digital settings
  • functional in cold applications
  • ensure control of the compressor icing and ventilation
  • configurable digital inputs (door alarm)
  • reducing energy consumption function Save Energy
  • quick programming with HOTKEY function
  • TTL output that allows connection to monitoring systems Xweb
 XT121C Multifunctional digital Controller temperature in 2 steps
Output: 3 relays
NTC /PTC PT1000/ termocuple
  • digital settings
  • functional in applications for heating / cooling
  • reducing energy consumption function Save Energy
  • quick programming with HOTKEY function
  • TTL output that allows connection to monitoring systems Xweb
 WING
XW60K
Split digital controller
on/off
Output:4 relays
NTC:NG6 –40C-+100C
PTC: S6SH –50C-+150C
  • digital settings
  • functional in cold applications
  • ensures the control of the compressor, icing, ventilation and lighting
  • special digital input for door
  • Configurable input for external alarms, starting icing,
  • allows remote connection with V620 keypad or CX620
  • reducing energy consumption function Save Energy
  • quick programing with HOTKEY function
  • TTL output that allows connection to monitoring systems Xweb
 XH260L Compact digital controller
Output:6 relays
NTC:NG6 –40C-+100C
XH20P: 0…99%RH, 4…20mA Out
  • digital settings
  • functional in applications for heating / cooling
  • ensures the control of the compressor, icing, ventilation and lighting, the resistances of a heating and humidifying / dehumidification equipment
  • special digital input for door
  • Configurable input for external alarms, start icing, on / off,
  • reducing energy consumption function Save Energy
  • quick programming with HOTKEY function
  • TTL output that allows connection to monitoring systems Xweb
 XLR170 Compact controller
Output:6 relays
NTC:NG6 –40C-+100C
PTC: S6SH –50C-+150C
  • compact solution to drive an installation phase of max 4kW
  • special for cold applications
  • digital settings
  • ensure control of the compressor icing and ventilation
  • equipped with auxiliary outputs for alarms and lighting
  • reducing energy consumption function Save Energy
  • quick programming with HOTKEY function
  • TTL output that allows connection to monitoring systems Xweb
 XJP60D Temperature acquisition module NTC:NG6 –40C-+100C
PTC: S6SH –50C-+150C
  • 6 inputs for temperature sensors
  • 3 programmable digital inputs
  • Connection X-REP / Hot Key
  • Built-in RS485 serial output